Gas Log Sets

Gas Log Sets

Vented and vent-free sets, specced to your firebox, your flue and your gas supply. We measure the opening, confirm what your fireplace is actually rated to take, and install it — we do not sell you a box and wish you luck.

Start Here

Two Very Different Products

“Gas logs” covers two things that are not really the same product. A vented set is a fire you look at. A vent-free set is a heater. They install differently, they are permitted differently, and one of them is not allowed in every room.

Which one is right depends on your fireplace, your room, and what you actually want out of it. That is a five minute conversation, and it is worth having before you buy.

Option One

Vented Gas Logs

Burns with the damper open, up a working chimney, exactly like a wood fire does. The flame is tall, yellow and lazy, and it is the closest thing to a real wood fire you can get out of gas.

Because the flue is open, most of the heat goes up it. Buy a vented set for the look, not for the heating bill.

  • Needs a working, correctly sized flue and a damper that opens
  • Best flame appearance by a wide margin
  • Very little heat into the room
  • Higher BTU inputs available
  • No room-size restriction

Option Two

Vent-Free Gas Logs

Burns with a precisely engineered flame that produces almost no products of combustion, so the exhaust stays in the room. Nearly all of the fuel becomes heat, which makes it a genuine supplemental heater.

That is also why the rules around it are strict. Every listed vent-free set has an oxygen depletion sensor that shuts the gas off if room oxygen drops, and the set has to be matched to the volume of the room it sits in.

  • Real heat — it will warm the room
  • Flame is shorter and more disciplined than a vented set
  • Oxygen depletion sensor required and non-negotiable
  • Sized to room volume; not for bedrooms or bathrooms
  • Some jurisdictions restrict them — we check yours first

Size It Yourself

Gas Log Builder

Measure the opening, tell us how it vents and what you burn, and this will work out the set size your firebox takes and show you what we can put in it. It is a starting point, not a quote — we confirm every measurement on site before anything is ordered.

Step 1

Measure the firebox opening

All four in inches. Fireboxes taper, so the front and rear widths are usually different — the rear is what limits the set.

Not sure what to measure? Print the measurement worksheet (PDF) — it asks for the twelve figures we actually need.

Step 2

Vented or vent-free?

Two different products. A vented set is a fire you look at. A vent-free set is a heater. The difference, explained.

Step 3

What is your gas?

How should it light?

IPI (electronic ignition) means no pilot burns when the fire is off. Sets that offer it are listed first either way.

Send It Over

Get a Price on This

Pick the sets you like above and they land in this form with your measurements. Add a photo or two of the fireplace and we will come back with a set, a price and a date — usually the same day. Nothing here commits you to anything.


Fitment

What We Check Before You Buy

Gas log set burning in a fireplace

The firebox decides the set

Measurements

A log set is sized to the firebox, not to the room. We need the front width, the rear width, the depth and the height at the front and back — and the rear width is the one everybody forgets, because fireboxes taper.

Then we confirm what your fireplace is listed for. A factory-built prefab firebox has its own manual and it will say, in writing, whether a gas log set is permitted in it and up to what input.

  • Front and rear width, depth, height. Fireboxes taper — both widths matter.
  • Damper condition. A vented set needs one that opens and stays open.
  • Gas type and line size. Natural gas and propane sets are not interchangeable.
  • Existing gas key valve and whether it is where you can reach it.
Gas log installation in progress

Then we install it properly

The install

Burner set level and centered, logs placed exactly the way the manufacturer’s diagram shows, ember material where it belongs and nowhere else, connection leak tested, and the whole thing run and observed before we leave.

Log placement is not decorative. Logs sitting where the manual does not show them will make soot and can push carbon monoxide where you do not want it. This is the single most common thing we find wrong on a set somebody else installed.

  • Gas work by licensed personnel and leak tested.
  • Damper clamp where the listing requires one.
  • Carbon monoxide alarm confirmed on the level before we leave.
  • Remote or wall control set up and demonstrated.

Under the Logs

Burners & Ignition

The log set is what you see; the burner and valve decide how it lights. IPI (intermittent pilot ignition) means electronic ignition: no pilot burns when the fire is off, it starts from a remote or switch, and it saves gas all year. Every set in the builder above lists its burners and whether IPI is available.

Real Fyre 33

Valve codes: -01V electronic variable (vent-free) · -02 IPI on/off remote · -2VT IPI variable remote · -A manual standing pilot · -11 / -12 on/off remote · -15 / -17 variable remote. EPK kits add electronic ignition to vented burners.

  • G10 Burner SystemIPIvent-freemanual; standing pilot + variable flame remote (-15); on/off remote standing pilot (-12, per set pages); electronic ignition + variable flame remote (-01V)
  • G10 Stainless Steel Burner SystemIPIvent-freemanual; standing pilot + variable flame remote (-15); electronic ignition + variable flame remote (-01V)
  • G18 Burner SystemIPIvent-freemanual; standing pilot + variable flame remote (-15); electronic ignition, on-demand pilot + variable remote (-01V)
  • G19A Burner SystemIPIvent-freestanding pilot + on/off remote (-12, per set pages); standing pilot + variable flame remote (-15); electronic ignition, on-demand pilot + variable remote (-01V)
  • ODG15 Ventless Outdoor Burner SystemIPIvent-freeon/off electronic pilot (-02); electronic ignition + variable flame (-02V)
  • G21 Contemporary Burner (G21-GL)vent-freestanding pilot + on/off remote (-12)
  • G23 Contemporary Spheres BurnerIPIvent-freestanding pilot + on/off remote (-12); electronic variable flame control (-01V)
  • G9 Burner Systemvent-freemanual; standing pilot + on/off remote (-12); standing pilot + variable flame remote (-15)
  • G8E Burner Systemvent-freemanual; standing pilot + on/off remote (-12); standing pilot + variable remote (-15, not on 9,500 BTU model)
  • G4 / G4X Burner SystemsIPIventedmatch lit (NG only); manual valve standing pilot (-A); millivolt standing pilot + variable remote (-17); IPI electronic + on/off remote (-02); IPI electronic + variable remote (-2VT)
  • G45 & GX45 Burner SystemsIPIventedmatch lit (NG only); manual valve standing pilot (-A); millivolt standing pilot + variable remote (-17); IPI electronic + on/off remote (-02)
  • G45 Stainless Steel Burner Systems (outdoor)IPIventedmatch lit (NG only); manual valve standing pilot (-A); IPI electronic + remote (-02)
  • G45 Glass Burner Systems (G45-GL)IPIventedmatch lit (NG only); manual (-A); millivolt on/off remote (-11); millivolt variable remote (-17); IPI + on/off remote (-02); IPI + variable remote (-2VT)
  • G45 See Thru Glass Burner Systems (G45-2-GL)IPIventedmatch lit (NG only); manual (-A); millivolt on/off remote (-11); millivolt variable remote (-17); IPI + on/off remote (-02); IPI + variable remote (-2VT)
  • G45-2 & GX45-2 See Thru Burner SystemsIPIventedmatch lit (NG only); manual (-A); millivolt on/off remote (-11); millivolt variable remote (-17); IPI + on/off remote (-02)
  • G45 See Thru Stainless Steel Burner Systems (G45-2-SS, outdoor)IPIventedmatch lit (NG only); manual (-A); IPI + remote (-02)
  • G46 Burner SystemsIPIventedmanual standing pilot (-A); millivolt on/off remote (-11); millivolt variable remote (-15); millivolt variable remote (-17); IPI + on/off remote (-02); piezo ignition
  • G31 Burner Systems (three-tiered)IPIventedmanual standing pilot (-A); millivolt variable remote (-17); IPI + on/off remote (-02); IPI + variable remote (-2VT)
  • G52 Burner Systems (Radiant Fyre)IPIventedmatch lit (NG only); manual standing pilot (-A); millivolt variable remote (-17); IPI + on/off remote (-02); IPI + variable remote (-2VT)
  • G52 Stainless Steel Burner Systemsventedmatch lit (NG only); manual standing pilot (-A); remote (type not specified)
  • P45 Burner Systems (tapered dual pan)ventedmatch lit (NG only); manual standing pilot (-A); millivolt variable remote (-17)
  • PB Burner Systems (P / PB flame pan)IPIventedmatch lit (NG only); manual standing pilot (-A); millivolt variable remote (-17); IPI + on/off remote (-02)
  • EPK-2(P) Automatic Remote Lighting Safety Pilot kitIPIventedintermittent pilot ignition, non-standing flame-sensing pilot; RR-1A on/off remote
  • EPK-2M-AD(LP) 110V Electronic Valve KitIPIvented110V electronic, non-standing flame-sensing pilot; manual on/off (wall switch sold separately)
  • EPK-2V(P)-TR 110V Electronic Valve KitIPIventedintermittent pilot ignition; variable flame remote + receiver + transformer
  • EPK-3V(P)-TR 110V Electronic Valve KitIPIventedintermittent pilot ignition; variable flame remote + receiver + transformer
  • SPK-26(P) Safety Valve with Standing Pilotventedstanding pilot safety valve; manual on/off
  • APK-10(P) High Capacity Automatic Safety Pilotventedsafety pilot (standing); RR-1A on/off remote
  • APK-11(P) Automatic Safety Pilotventedsafety pilot (standing); RR-1A on/off remote
  • APK-15(P) Automatic Safety Pilot w/ Variable Remoteventedsafety pilot (standing); VR-1A variable remote
  • APK-17(P) Low Profile Automatic Safety Pilotventedsafety pilot (standing); VR-1A variable remote
  • AV-17 & AV-18 Manual Valvesventedmanual on/off valve (match lit)
  • AV-30 Straight Line Gas Valve with Keyventedmanual key valve (match lit)
Hargrove 14

Valve 3F = electronic ignition with variable remote.

  • E-Burnervented, 15–42″match light, safety pilot, latch-tap or variable safety pilot with remote, millivolt
  • H-Burnervented, 18–36″match light, safety pilot, safety pilot with remote, millivolt
  • Hidden ControlIPIvented, 18–36″variable safety pilot with remote, or electronic ignition with variable remote (3F)
  • System 4 (propane)vented, 18–42″safety pilot, with or without remote
  • StealthIPIvented, 18–36″variable safety pilot with remote, or electronic ignition with variable remote (3F)
  • See-Thruvented, 18–48″match light, safety pilot, safety pilot with remote, millivolt
  • Full Panvented, 18–30″match light, safety pilot, safety pilot with remote, millivolt
  • Pinnacle (Rumford)IPIvented, 12–30″safety pilot with remote, or electronic ignition with variable remote (3F)
  • Kivavented, 10″match light
  • Double Stack / Triple Stackvented, 24–60″match light, millivolt
  • Ember Supreme (natural gas)vented, 30–60″match light, safety pilot, high-capacity millivolt
  • Summit Oakvented, 36–48″match light, high-capacity millivolt
  • Vent-free burnersIPIvent-freemanual, variable, millivolt with remote, and electronic ignition on the Ember Glow, Cimarron, Birch, Charleston and Frontier sets
  • Add-on electronic ignition kitsIPIventedDEI-PO (wall switch), MEI-PO (variable remote), AEI-PO (variable remote), Enclosed EI indoor / outdoor — no standing pilot
Grand Canyon 11
  • 2 Burner / 3 BurnerIPIvented, 18–60″ / 18–42″match lit, safety pilot, millivolt, battery electronic IPI (MVKEIK), 24V electronic (EIS)
  • See-through 2/3 burnerIPIventedas above, controls for two-sided fireplaces
  • Jumbo / Jumbo SlimlineIPIvented, 24–120″as above, including the battery IPI kit
  • Kiva burnerIPIvented, 18–30″as above
  • Glass burnerIPIventedas above
  • Lava burner (GlowFire)IPIvented, 18–36″electronic ignition, on/off or variable
  • Bedrock TraditionalIPIvented, 48–72″SIT ProFlame II intermittent pilot
  • Bedrock ContemporaryIPIvented, 24–96″SIT ProFlame II with remote and app
  • Bedrock II VentlessIPIvent-free, 24–60″SIT ProFlame II
  • VulcanIPIvent-free, 18–30″millivolt, variable, or electronic variable IPI
  • Outdoor burnersIPIoutdoor2/3 burner, Tee-Pee, H, T, ring and drop-in pans; WBECS 12V hot-surface or EIS-Outdoor electronic, or match lit
Eiklor Flames 10

Every Eiklor burner ships with a factory-mounted valve chosen from the list below.

  • 304-1IPIvented, 18–30″one-burner half pan
  • 304-2IPIvented, 18–36″two-burner half pan
  • ULTIMATE 5IPIvented, 18–36″five-burner
  • MOMBOIPIvented, 32–120″large two-burner; battery IPI to 80,000 BTU, 110V electronic above that
  • See-ThruIPIventedany of the above with dual controls
  • KivaIPIvented, 18–30″one main + three vertical burners
  • Linear / PrincessIPIvented, 18–120″linear pipe or flat pan
  • High RizeIPIvented, 3–7 ftteepee burner
  • FirepitIPIindoor/outdoor, 16–96″110V automatic electronic ignition
  • Valve choices (all Eiklor burners)IPI—match lit, safety pilot, millivolt wall switch, millivolt remote, variable remote, battery IPI, 110V automatic electronic ignition

Lines We Carry

Four Brands, Four Reasons

We do not carry one brand and then bend every firebox to fit it. These four cover the ground between them — the custom stainless burner, the widest catalogue of log styles, the realism specialist, and the one to call for outdoor and oversized. Which set you end up with is decided by your firebox and your gas supply, not by what happens to be in the van.

Eiklor Flames gas logs Real Fyre gas logs Hargrove gas logs Grand Canyon gas logs

Come See It

See One Lit

Log sets are one of the products where a photograph genuinely lies. Come stand in front of a few of them burning. Bring your measurements and we can spec it the same visit.